Part Number Hot Search : 
FBR46 8M07C HMC128G8 CT2566 ADC0094 AD6432 K1V10 E100A
Product Description
Full Text Search
 

To Download SY15-S3 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 SYNCHRONOUS EQUIPMENT STRATUM 3 CLOCK UNIT WITH HF OUTPUTS - SY15-S3
SY15-S3
Date: 5/15/2001
*
INTRODUCTION
The SY15-S3 is an accurate time and frequency source, with high frequency, outputs that has been designed as a subsystem level module. The module is designed to work within ATM, SONET, SDH, and wireless systems environments where synchronization is vital. The SY15-S3 is an enhanced version of SY01 and is designed for Stratum 3 applications, but also holds certain features that can make it useful for SONET Minimum Clock (SMC) or other kinds of system clocks.
*

FEATURES
A synchronization solution for timing, jitter and wander concerns in a single module. Complies with ITU-T Recommendations G.813 and ETSI-ETS 300 462-4 and Bellcore GR-1244-CORE for Stratum 3 applications. Supports three modes of operation: Locked to any of References (1-5), Holdover and Free-run. Accepts reference inputs from up to five independent sources from 8 kHz to 77.76 MHz. Provides three high frequency outputs up to 622.08 MHz. Loop filtering utilizing application specific software in the digital signal processor (DSP). Continuously monitors and evaluate input reference signals. Creates a history buffer for Holdover mode operation. Manual or Automatic selection between timing modes. Alarm and status signal. Host interface and JTAG port. Small dimensions of 1.8 x 1.8 x 0.60 inch.
*
APPLICATION
The SY15-S3, a Synchronous Equipment Clock (SEC), fulfills clock regeneration function for STRATUM 3 equipment for: ATM, SDH, PDH, and SONET networks. It was designed for network system manufacturers such as: Access Switches, Core Switches, Cross Connects, Digital Multiplexers-Exchangers, and SDH/SONET equipment. The unit is also suitable for designs where a high frequency outputs are required. Wherever a Timing unit with high performance specifications is required, the SY15-S3 can be embedded within the network system and provide all necessary frequencies and interfaces.
RALTRON ELECTRONICS CORP. ! 10651 N.W.19 St ! Florida 33172 ! U.S.A. Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: sales@raltron.com ! Internet: http://www.raltron.com
th
SYNCHRONOUS EQUIPMENT STRATUM 3 CLOCK UNIT WITH HF OUTPUTS - SY15-S3
J-TAG
EX REF1 EX REF2 EX REF3 EX REF4 EX REF5
DSP MUX PD1 FLASH RAM DAC 1 OCXO
/N
CNT1 CNT2 CNT3
CONTROL LOGIC
ALARM OUT PLL UNLOCK REF 1 to REF 5
HIGH FREQUENCY SYNTHESIZER
OUT 1 OUT 2
CPLD
DIV
OUT 3
ENOUT1
ENOUT3 ENOUT2
Figure 1. - The functional block diagram of SY15-S3
*
DESCRIPTION
The SY15-S3 synchronization module is a Digital PLL (DPLL), which utilizes application specific software in the digital signal processor (DSP). The DSP is complemented by fast hardware logic (CPLD) where all multiplexers, counters, dividers, phase detectors, and other control logic circuits are completely implemented. The functional block diagram with configuration is shown in figure 1. The configuration utilizes one DPLL with an OCXO as onboard oscillator, and one high frequency synthesizer. The OCXO is driven by a digital-to-analog converter (DAC1) and provides the accurate and stable signal under all conditions. The output frequencies are generated by the synthesizer that uses a VCXO and high frequency dividers to provide the output frequencies on all three outputs. For other configurations, please contact Raltron.
" The module operates in the following four timing modes:
Free-run In this mode the unit is unlocked to either of the inputs. The accuracy of the output frequencies in this mode is 4.6ppm. Free-run mode is typically used when a master clock source is required, not valid history of data for the Holdover mode, or immediately following system power-up before network synchronization is achieved. In the Freerun Mode, the SY15-S3 provides timing and synchronization signals that are based on the accuracy of on-board oscillators only, and are not synchronized to the reference signals. Holdover In this mode the module has lost its reference inputs and is utilizing stored timing data, called history, to control the output frequency. Holdover Mode is typically used while network synchronization is temporarily disrupted. In Holdover Mode, the SY15-S3 provides timing, based on data from the history buffer, while unlocked to an external reference signal. The history data is determined while the device is locked to an external reference signal. The stability of the output signal in holdover mode depends primarily on the stability of on-board oscillator and environment effects where the clock is mounted. The SY15-S3 uses an OCXO as an on-board oscillator but other types of oscillators are available.
RALTRON ELECTRONICS CORP. ! 10651 N.W.19 St ! Florida 33172 ! U.S.A. Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: sales@raltron.com ! Internet: http://www.raltron.com
th
SYNCHRONOUS EQUIPMENT STRATUM 3 CLOCK UNIT WITH HF OUTPUTS - SY15-S3
Locked to EX REF.1 In this mode the output of the module is phase locked to input reference 1. Locked to EX REF.2 In this mode the output of the module is phase locked to input reference 2. Locked to EX REF.3 In this mode the output of the module is phase locked to input reference 3. Locked to EX REF.4 In this mode the output of the module is phase locked to input reference 4. Locked to EX REF.5 In this mode the output of the module is phase locked to input reference 5. The EX REF1 to EX REF5 Modes are typically used when a slave clock source is synchronized to the network. In these modes, the SY15-S3 provides timing signals, which are synchronized, to one of five references inputs (EX REF1 or EX REF5). The input reference signals may have a variety of nominal frequencies, which is typically specified by the end user. When the modes are selected the unit goes through a reference evaluation, and then a frequency acquisition, and finally to phase locking.
Local Reference Oscillator
Depending on the type of clock, a local reference oscillator is selected. For example: for a Stratum 3 type of clock, the local oscillator can be an AT-cut OCXO or in some cases a good TCXO that meets this standard requirements for frequency drift and jitter noise. For other standards please contact the factory.
*
Control
The external control is available for the user to control the operation of the SY15-S3. The three external inputs CNT1, CNT2 and CNT3 provide this feature. Below, the truth table shows behavior of the SY15-S3 module according to the control inputs states.
CNT3 0 0 0 0 1 1 1 1 CNT2 0 0 1 1 0 0 1 1 CNT1 0 1 0 1 0 1 0 1 MODE OF OPERATION Free-run Locked to EX REF1 Locked to EX REF2 Locked to EX REF3 Locked to EX REF4 Locked to EX REF5 Ignored Holdover
*
Input References
The SY15-S3 module accepts five input references EX REF1 to EX REF5. End users can specify the frequencies within a range of 8 kHz to 77.76 MHz. The input reference signals are HCMOS/TTL levels with timing characteristic in according to Bellcore GR-1244-core 3.2.1.R3-1 or equivalent standards. Please note that the end user must specify the input frequencies at the time of order.
*
Output Signals
The SY15-S3 module provides three high frequency output signals OUT1, OUT2 and OUT3. The outputs are generated by the high quality low jitter VCXO and scaled by the output frequency converters. The quality of the output significantly depends on the VCXO oscillator and special care was taken to define its specification. The OUT1 and OUT2 are buffered from VCXO output while the OUT3 is derived by dividing the output frequency of the
RALTRON ELECTRONICS CORP. ! 10651 N.W.19 St ! Florida 33172 ! U.S.A. Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: sales@raltron.com ! Internet: http://www.raltron.com
th
SYNCHRONOUS EQUIPMENT STRATUM 3 CLOCK UNIT WITH HF OUTPUTS - SY15-S3
VCXO. The division ratio can be from 1 to 8. All outputs are complementary PECL and can be enabled and disabled by external pins ENOUT1, ENOUT2 and ENOUT3.
*
SPECIFICATIONS
Mechanical Power Supply Warm Up Current Supply Steady State Current Supply Operating Temperature Storage Temperature Humidity Internal Oscillators Number of Inputs Input reference frequency Signal Level Time Reference characteristics Number of Outputs Output 1 Output 2 Output 3 Signal Level Jitter Tolerance Phase Transient Tolerance Wander Generation Wander Tolerance Jitter Generation and Transfer Wander Transfer Jitter <1ps RMS 4.6ppm 3.7x10-7 for 24hours 50x10-9 280x10-9 40x10-9 0.1Hz <30sec 1x10-11 2"(D)x2"(W)x0.75"(H) 1.8"(D)x1.8"(W)x0.60"(H) 5VDC +3.3VDC TBD TBD -20C to 70C -40 to 85C 5% to 95% non-condensing OCXO or TCXO 5 8kHz to 77.76MHz HCMOS/TTL Compatible 3 155,52 or 622.08MHz 155,52 or 622.08MHz 155,52 or 622.08MHz PECL Hermetically Sealed Metal box Module on PCB Regulated for PECL Only with OCXO Other ranges available on request
General Specifications
Input Signals
User selectable Bellcore: GR-1244-core 3.2.1.R3-1 User define Same as Output 1 Output 1 divided by 1,2,4 or 8 Bellcore: GR-1244-core 4.2 ITU-T: G.813 Bellcore: GR-1244-core 4.4 Bellcore: GR-1244-core 5.3 ITU-T: G.812 Bellcore: GR-1244-core 4.3 ITU-T: G.812 Bellcore: GR-1244-core 5.5 ITU-T: G.812 Bellcore: GR-1244-core 5.4 ITU-T: G.812 On all outputs within the bandwidth 12kHz-20MHz GR-1244-core 5.1 ITU-T: G.812 TCXO: 3.7x10-7 for 24 hours @ T10C Bellcore: GR-1244-core 5.2 ITU-T: G.812 TCXO: 280x10-9 within T10C 1x10-6 -20C to 70C Bellcore: GR-1244-core 5.2 ITU-T: G.812 or adjustable GR-1244-core 3.7
Output Signal
Signal Quality Performance
Frequency Output Performance
Free run accuracy Holdover frequency stability Initial Offset Temperature Drift DPLL bandwidth Lock Time Lock accuracy
RALTRON ELECTRONICS CORP. ! 10651 N.W.19 St ! Florida 33172 ! U.S.A. Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: sales@raltron.com ! Internet: http://www.raltron.com
th
SYNCHRONOUS EQUIPMENT STRATUM 3 CLOCK UNIT WITH HF OUTPUTS - SY15-S3
VCC EX REF 1 EX REF 2 EX REF 3 EX REF 4 ENOUT2 OUT2 OUT2 GND ENOUT3 OUT3 OUT3 PVDD ENOUT1 OUT1 OUT1 GND
34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
HOLDOVER REF 1 REF 2 REF 3 REF 4 REF 5 FREERUN RESET GND EX REF5 ALARM OUT REV CNT 1 CNT 2 CNT 3 AUTS PLL UNLOCK
Figure 2 - Bottom view
*
PIN ASSIGNMENT
On the picture below it is shown the pin-out for the SY15-S3. The design is done in such a way that is can support basically any other pin-out without changes in the hardware. For other pin-out requirement please contact the Raltron.
Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
Name HOLDOVER REF 1 REF 2 REF 3 REF 4 REF 5 FREERUN RESET GND EX REF 5 ALARM OUT REV CNT 1 CNT 2 CNT 3 AUTS PLL UNLOCK GND OUT1 OUT 1 ENOUT1 PVDD OUT3 OUT3 ENOUT3 GND OUT2 OUT2 ENOUT2 EX REF 4 EX REF 3 EX REF 2 EX REF 1 VCC
Description Holdover Signal -> the output is high when the unit is in holdover mode Reference 1 Signal -> the output is high when the unit is using the reference 1 Reference 2 Signal -> the output is high when the unit is using the reference 2 Reference 3 Signal -> the output is high when the unit is using the reference 3 Reference 4 Signal -> the output is high when the unit is using the reference 4 Reference 5 Signal -> the output is high when the unit is using the reference 5 Free-run Signal -> the output is high when the unit is in the free run mode Reset -> input signal, reset the module Ground External Reference 5 Input -> the input signal from reference 5 Alarm signal -> the output is high when there is an alarm in the module. Revertive Input-> to set revertive mode (low), to disable revertive mode set the pin high. Control Input 1 -> the external input for selecting mode of the unit - see table above. Control Input 2 -> the external input for selecting mode of the unit - see table above. Control Input 3 -> the external input for selecting mode of the unit - see table above. Automatic Switching Input -> to select automating switching between references (low), to disable set high. PLL Unlocked Signal -> the output is high when the unit is not locked to any of the references Ground Output 1 complementary -> Complementary signal from the Output 1 Output 1 -> Signal from the O1 Enable Output 1-> Signal enable output 1 when low PECL VDD -> +3.3V, power supply for PECL and VCSO Output 3 complementary -> Complementary signal from the Output 3 Output 3 -> Signal from the O3 Enable Output 3-> Signal enable output 3 when low Ground Output 2 complementary -> Complementary signal from the Output 2 Output 2 -> Signal from the O2 Enable Output 2-> Signal enable output 2 when low External Reference 4 Input -> the input signal from reference 4 External Reference 3 Input -> the input signal from reference 3 External Reference 2 Input -> the input signal from reference 2 External Reference 1 Input -> the input signal from reference 1 Positive Voltage Supply
For other pin-out configurations contact the factory!
RALTRON ELECTRONICS CORP. ! 10651 N.W.19 St ! Florida 33172 ! U.S.A. Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: sales@raltron.com ! Internet: http://www.raltron.com
th
SYNCHRONOUS EQUIPMENT STRATUM 3 CLOCK UNIT WITH HF OUTPUTS - SY15-S3
* MECHANICAL DIMENSIONS
Figure 3 - The mechanical dimensions.
Figure 3. shows the mechanical dimension of the SY15-S3 module. The module can be supplied in two different types of packaging: Metal box Module without packaging
The dimensions shown on figure are valid for first and second type of packaging, the actual dimensions for the third type are 1.8 x 1.8 x 0.60" keeping the pin-out dimensions the same for all of three. The label on the module shows part number, factory name, week and year of production. The height of the module is 0.50" if a TCXO is used as the reference oscillator!
RALTRON ELECTRONICS CORP. ! 10651 N.W.19 St ! Florida 33172 ! U.S.A. Tel: 305 593-6033 ! Fax: 305-594-3973 ! e-mail: sales@raltron.com ! Internet: http://www.raltron.com
th


▲Up To Search▲   

 
Price & Availability of SY15-S3

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X